INSTALLATION PROCEDURE
Contact us
1. Using the packaged 11 inch tie-wrap, encircle the base of      
    the Cellar Saver ( where it is marked "tie")  and the vertical    
    flow pipe about level with the drain tile. Make sure that the     
   swing arm moves freely.  

2. Determine which set of wires you'll be using if Model CS         
    2029 W is used. There are three wires coming from the          
     contact. The WHITE wire is COMMON, The
RED wire is N/O  
     or
NORMALLY OPEN, The GREEN wire is N/C or                 
       
NORMALLY CLOSED.

3, Run the alarm wires to the panel of the security system and   
    connect them to a 24 hour zone. If using the
RED/WHITE       
    combination (
N/O) the resistor for the zone is placed in          
    parallel (across) the two terminals. If you are using the           
    
GREEN/WHITE combination, the resistor is placed in              
    series with the terminals or in line with the wires.

4. After installation, test the unit by picking up the float and        
    making sure the alarm panel sounds both an audible device  
    and reports to a central station.
It's imperative that the       
    alarm system be monitored.

5. FISH TANK...The easiest way to attach the Cellar Saver to     
    a fish tank is to place a small section of PVC pipe into the      
    tank and use the tie-wrap to secure it. The
DATA sheet page
    will give other ideas about using pipe strapping for mounting.