| 1. Using the packaged 11 inch tie-wrap, encircle the base of the Cellar Saver ( where it is marked "tie") and the vertical flow pipe about level with the drain tile. Make sure that the swing arm moves freely. 2. Determine which set of wires you'll be using if Model CS 2029 W is used. There are three wires coming from the contact. The WHITE wire is COMMON, The RED wire is N/O or NORMALLY OPEN, The GREEN wire is N/C or NORMALLY CLOSED. 3, Run the alarm wires to the panel of the security system and connect them to a 24 hour zone. If using the RED/WHITE combination (N/O) the resistor for the zone is placed in parallel (across) the two terminals. If you are using the GREEN/WHITE combination, the resistor is placed in series with the terminals or in line with the wires. 4. After installation, test the unit by picking up the float and making sure the alarm panel sounds both an audible device and reports to a central station. It's imperative that the alarm system be monitored. 5. FISH TANK...The easiest way to attach the Cellar Saver to a fish tank is to place a small section of PVC pipe into the tank and use the tie-wrap to secure it. The DATA sheet page will give other ideas about using pipe strapping for mounting. |
|||||||||||||||||||||||||
| Sump Pump Failure Warning Device! |